Measurement accuracy
|
Level 1.5
|
Repeatability
|
0.2%.
|
Flow rate range
|
Below DN200 (inclusive) 0.3- 4m/S; above DN200 0.3-6m/s
|
Measurement principle
|
Principle of ultrasonic propagation time difference, dual CPUs working in parallel, 4-byte floating point operation
|
Measurement period
|
500mS (2 times per second)
|
Working power supply
|
Isolated DC8-36V or AC85-264V
|
Signal input
|
3 channels of 4-20mA analog input, which can input pressure, liquid level, temperature and other signals; 2 channels of three-wire platinum resistors |
|